Idiomas disponibles

16"
(40.6 cm)
2-1/4"
(5.7 cm)
9" (22 cm)
1-1/4"
(3.2 cm)
3" (7.6 cm)
1-1/2" OD
Product Information
Applicable product:
Integral tile flange and heater, left drain
Integral tile flange and heater, right drain
Fixture*:
Bathing well:
Basin area, bottom
42" (106.7 cm) x 20" (50.8 cm)
Basin area, top
51" (129.5 cm) x 24" (61 cm)
Weight
160 lbs (72.6 kg)
To overflow:
Water depth
14" (35.6 cm)
Capacity
60 gal (227.1 L)
* Approximate measurements for comparison only.
V
Pump: 1-speed
120
Heater: 1.5 kW
120
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Heater
Locate the outlets behind the whirlpool and within 24" (61 cm)
of the pump and heater.
1038566-1-B
K-1357-HL
60" (152.4 cm)
1" (2.5 cm)
2-1/2"
(6.4 cm)
K-1357-HL
K-1357-HR
Hz
A
60
7
60
12.5
120 V, 15 A, 60 Hz
120 V, 15 A, 60 Hz
No change in measurements if connected with drain
illustrated. (K-7161-AF or K-7161M-AF)
21-1/4"
(54 cm)
20"
(50.8 cm)
Notes
Install this product according to the installation guide.
Floor support under this product must provide for a minimum of
51 lbs/square foot (251 kg/square meter) loading.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions
are nominal.
2
1-1/4"
(3.2 cm)
1/2" R.
(1.3 cm)
Integral Flange
Detail
32" (81.3 cm)
Kohler Co.

Publicidad

loading

Este manual también es adecuado para:

K-1357-hr