Clamp set-up on door n°1
step 4
- Mount the clamps 6mm from the edge of the glass.
- The clamps must be left in the position indicated in the drawing, ending with the
stopper on the left.
!
!
6
6
G
- Adjust the plate bolts with the Segmenta
key.
- Adjust the clamp bolts with the 4mm
C
Allen key, applying 15 NM until the glass
is held fi rm.
1
H
T
T
A´
E
15 N/M
28