step 10
- Adjust the door aligner PLVD with 3mm Allen key.
- Adjust the height of the doors, aligning them with each other.
- Once they have been adjusted, counter-turn at the carrier and the guide with
Segmenta key.
- The gap shown in the drawing must be considered:
> Gap between the upper track and door: 10mm.
> Gap between the lower track and door: 8mm.
> Gap between doors: 3mm.
> Gap between door and opening: 7.5mm.
> Gap between cap and opening: 6mm.
10
6
7.5
6
8
Views of the system installed, closed and open.
1
34

Door adjustment

3
1
2
2
3
Y
3
3
4
Z
10
7.5
3
4
8
6
6