Specifications
Model No.
GAJ002AC
Description
Automatic faucet with soap dispenser
DC:6V(4AA alkaline batteries)
Power Suplly
AC:220V-240V;50/60Hz
DC:≤0.18-0.33mW
Static Power Consumption
Sensing for water:25±5CM
Sensing Range
Sensing for soap:10±2CM
Water Pressure
0.5Bar-8 Bar
1℃-55℃
Ambient Temperature
G1/2"
Inlet
(based on white board)
(based on white board)
Trouble shooting
Symptom
Cause
The battery is exhausted
Water supply cut off
No water out
Dirt in the filter
Water pressure too low
There is still air in the soap tube
Too low ambient temperature,
the soap is easy to freeze
No soap out
The soap in the bottle is too little
The check valve is blocked
Water or soap
Dirt on the sensor window
will not turn off
Water supply is turned down
Too little
The filter is too dirty
water flow
Water pressure is too low
Too much
Water pressure is too high
water flow
Short cycles
Incorrect batteries
of battery
The light is broken
The circuit board is wet or signal
The indicator
line is wet
light is
The battery is exhausted
Poor connection of battery
Treatment
Change the battery
Check supply
Clean the filter
Raise the pressure
Sense the soap sensor
repeatedly until soap out
Fill in proper amount of warm
water (approximate 60℃)
Fill more soap
Replace the check valve
Clean the sensor
Adjust water supply
clean the filter
Raise the pressure
Adjust pressure
Change to 4AA
Alkaline batteries
Change the light or
circuit board
Dry out
Change the battery
Check battery connections