Installation
Warning :Before installing the new spout it is essential that you throughly flush
through the pipework in order to remove any remaining swarf,solder etc.
Failure to carry out this procedure could cause problems or damage to the
workings of the spout.
This product must not be modified in any way as this will invalidate the guarantee .
1. Screw off the rotary union,nut
and gasket from the faucet.
3. Fit wall bracket
Position the brackets onto the wall
and mark the position of the fixing holes.
Remove the brackets and drill suitable
holes for the wall plugs supplied .
Fit the wall plugs and brackets.
2. Fit the spout to the basin ensuring
the cables and hose are threaded
through the hole in the basin.
4. Attach the pump to bottle
Ensure the dispenser tube is located
inside the bottle and push the pump
the pump down firmly onto the bottle
until a loud "click" is heard .
Connect the dispensing cable from the
spout into the top connection on the pump.
Place pump into bracket .
OUT
IN
Position and fix the control box
5.
onto the wall surface .
7. Insert Batteries.
Remove the battery cover and insert
4AA battery case ensuring they are
inserted the correct way .Replace the
battery box cover and tighten the screw.
Push the holder into the battery case
wall bracket.
Installation
OUT
IN
6. Connect the hose with the rotary
union to the outlet of the control box.
8. Insert the case into the holder .
Push the holder into the battery
case wall bracket.