8.3 Storage of fault times

Faulty-state counter
The time passed from the generation of a fault
message till its acknowledgement is added in
hours.
After acknowledgement, this value will automatically
be recorded by the fault hour meter.
Fault hour meter
The fault hour meter adds all fault-state times
occurring during the total operation time of the set.
The current result of metering can be read in the
display mode in two blocks of three digits each
after calling the parameter Fh (see Chapter 5).
The maximum display capacity of the meter is
99,999.9 hours. The smallest interval storable is
0.1 hour = 6 minutes.
The memory cannot be erased.

8.4 Maintenance and repair

The following maintenance works and checks have
to be carried out in regular intervals:
Checking of filling level in the lubricant vessel
Regular checking of tightness in the system
components
Visual checking of lubrication state in bearings
Checking of electric cables for damage
Checking of electrical connections and contacts
The basic function of the control device and of
the system components can be verified by
releasing an intermediate lubrication process.
Checking of electrical connections in the case
of fault messages
Replace defective fuses only with new fuses of
identical performance
Any works beyond the above scope need
to be done by authorized Vogel Service
establishments.
The service life of the pump elements decisively
depends on the purity of the lubricants used.