MEASURING DC/AC
1.- Connect the red testing point to the jack signaled "Input",
and the black testing point to the jack signaled "COM". When
measuring up to 200 mA connect the red testing point to the jack
signaled "10A DC" when measuring up to 10A.
2.- Set the dial to uA, mA or A setting.
3.- Press the FUNC button and select DC or AC
4.- Press the RANGE button and select automatic or manual.
5.- Open the circuit and connect the testing points (in serial) to
the equipment to be measured.
6.- Read the value in the LCD display.
MEASURING DC
ENGLISH-09