Descargar Imprimir esta página

Cleaning And Disinfection - DENTSPLY XENO IV Instrucciones De Uso

Publicidad

Idiomas disponibles

Idiomas disponibles

1.3.5 Cure Xeno
®
IV Adhesive for 10 seconds
to completion/restorative material placement.
1.4 Completion: Place restorative material over the cured Xeno
restorative material manufacturer's directions.
2. Composite, ceramic and amalgam repairs (light cured composite resin and compomers)
2.1 Preparation, Cleaning: Roughen the fractured surface as much as possible with a
diamond bur. Create mechanical retention where possible. For best results, sandblast the
area to be repaired with an intraoral microetcher (50µ alumina). Rubber dam is
recommended with high speed evacuation. Rinse microetched areas for 15-20 seconds
with water. Air dry. NOTE: Bevel porcelain margins before etching. Etch ceramic
restoration repair area with hydrofluoric acid according to manufacturer's instructions.
2.2 Treatment of the Restoration: Rinse with water for 10 seconds. Air dry. NOTE: Apply
Calibra
®
Silane Coupling Agent to porcelain surfaces to be repaired following
manufacturer's instructions.
2.3 Application of Xeno
®
IV Adhesive: Apply and light cure
for direct restorations, see section 1.2-1.3.
2.4 Completion: Complete repair with placement and curing of desired shade(s) of light cured
composite restorative following manufacturer's directions.
3. Cavity varnish for use with fresh amalgam: When used as a cavity varnish, Xeno
Adhesive is not an amalgam adhesive.
3.1 Preparation: Finish preparation by removing existing restorations and/or caries.
3.2 Cleaning: Clean preparation and place Dycal
1.2.
3.3 Application of Xeno
®
IV Light Adhesive: Apply and light cure Xeno
described for direct restorations, see section 1.3.
3.4 Completion: Place and condense amalgam (e.g. Dispersalloy
per manufacturer's directions.
1
using a curing light. Proceed immediately
®
IV Adhesive as per
1
Xeno
®
IV Adhesive as described
®
IV
®
Liner if needed, following section 1.1 and
®
IV Adhesive as
®
Dispersed Phase Alloy) as
HYGIENE
Cross-contamination
• Do not reuse single use products. Dispose in accordance with local regulations.
• Reprocess reusable products as described below.

CLEANING AND DISINFECTION

To prevent Xeno
®
IV Adhesive bottle from exposure to spatter or spray of body fluids or
contaminated hands, or oral tissues, use of a protective barrier is recommended to avoid
package contamination. Repeated disinfection may damage label.
LOT NUMBER AND EXPIRATION DATE
1. Do not use after expiration date. ISO standard is used: "YYYY/MM"
2. The following numbers should be quoted in all correspondence:
• Reorder Number
• Lot number on bottle/unit dose
• Expiration date on bottle/unit dose
1 Check curing light for minimum curing output of at least 550 mw/cm
(peak absorption of the CQ photoinitiator).
©2014 DENTSPLY International. All Rights Reserved.
Manufactured by
DENTSPLY Caulk
38 West Clarke Avenue
Milford, DE 19963 USA
Tel.: 1-302-422-4511
www.dentsply.com
2
and a spectral output including 470nm
Distributed by
DENTSPLY D
T
GmbH
DENTSPLY Canada
E
REY
De-Trey-Str. 1
161 Vinyl Court
78467 Konstanz
Woodbridge, Ontario
Germany
L4L 4A3 Canada
Tel.: 49-7531-583-0
www.dentsply.de
Form #568003 (R 7/2/14)

Publicidad

loading