3 - SPECIFICATIONS
3.8 Warning symbols
General warning
Duty of reading the use & maintenance
manual
Compulsory head protection
4
- INSTALLATION, PRE-USE CONTROLS, DELIVERY AND HANDLING
4.1 Connection to the extension pole
•
Mount the extension pole (35) or (36) onto the tool (turn it clockwise). Screw it on the connection (12) until it is secured in
place. Turn it counter-clockwise to disassemble it.
•
Make sure that the air fi lter (27) located on the fi tting (26) is clean and correctly installed.
NOTE
Disconnect the tool from the air supply hose before carrying out this operation.
4.2 Connection to the air supply
•
Make sure that the safety catch (23) is engaged.
•
Set the pressure to 6÷7 bar (Olistar Metal Top); 6 bar (Olistar Tuono).
•
Check the fi lter and clean it if necessary.
•
Connect the supply hose to the fi tting (26) having fi rst made sure that the fi tting is thoroughly clean. The inside diameter
must be at least 6 mm.
WARNING!
Just use compressors or pneumatic equipment complying with the current laws and fi tted with a maximum safety valve.
NOTE
•
Make sure that the air hose is in perfect condition. It should not be bent or damaged in any way.
•
Adjust the air lubricator fi tted on the compressor so that a drop falls every 10 seconds. When necessary, add
Campagnola BIG FLU or low toxic FUDY FLU oil.
4.3 Control devices
To start the harvester, the safety catch (23) must be kept in its forward position. Press the control lever (24).
To stop the tool, release the control lever (24).
4.4 Delivery and handling
The tool is packed and transported from the manufacturer to the dealer using a 320x140x280 mm carton box. The total weight
is 1.380 kg, so the unit is easy to be handled.
WARNING!
The handling operations have to be carried out according to the current working environment safety regulations.
20 - 68
Compulsory adequate clothing
Compulsory hands protection
Compulsory feet protection