INITIAL SETUP

STEP 1: Set up the date and time page
When the PX1 is first powered up, the display
will default to the status page. Bypass this page
for the moment by pressing the Page button
three times to get to the date and time page.
The cursor will be blinking beneath the month
numeral in the display.
A. SETTING THE DATE: Set the month setting to the current month by pressing Up or Down to select
the correct month. Press Next once to move the cursor under the day field and press Up or Down
to select the correct day. Press Next again to place the cursor under the year field and select the
correct year if necessary.
B. SETTING THE TIME: Press Next once to move to the hour field of the time setting. Press Up or
Down to select the correct hour of your local time. Press Next once to move to the minutes field
of the time setting field and press Up or Down to select the correct minutes of the hour. Press
Next once again to move the cursor to the a.m./p.m. field of the time setting and select the
correct choice for your current time. Note: a.m./p.m. settings do not apply if 24-hour time format
is chosen.
C. SETTING THE 12/24 HOUR FORMAT: Press Next once again to move the cursor to the 12H/24H
field and select either 12H (standard/civilian time) or 24H (military time).
D. SETTING THE OUTPUT DISPLAY FORMAT: Press Next once again to move the cursor down to the
Output field and press Up or Down to select either W (Watts) or % (percentage of ballast output).
E. SETTING THE TEMPERATURE FORMAT: Press Next once again to move the cursor down to the
Degrees field and press Up or Down to select either F (Fahrenheit) or C (Celsius).
F. Press Enter to save all settings on this page.
STEP 2: Set up desired ballast output level
(dimming) for each zone.
Each zone's status line displays:
• Temp in degrees C (Celsius) or F (Fahrenheit)
• Power output setting (default cursor
position):
REFERENCE CHART
The ballasts being controlled have 6 dim settings.
Dim 1000[N_DIM] = {0, 600, 750, 825, 1000, 1150} 1000W ballast dim settings
W: OFF / 600 / 750 / 825 / 1000 / 1150
%: OFF / 60% / 75% / 82.5% / 100% / 115%
Dim 750[N_DIM] = {0, 400, 500, 600, 750, 825} 750W ballast dim settings
W: OFF / 400 / 500 / 600 / 750 / 825
%: OFF / 60% / 75% / 82.5% / 100% / 115%
Dim 600[N_DIM] = {0, 275, 400, 440, 600, 660} 600W ballast dim settings
W: OFF / 275 / 400 / 440 / 600 / 660
%: OFF / 60% / 75% / 82.5% / 100% / 115%