Disconnect the device from power supply before proceeding with installation.
Protect the device with a 30mA RCD circuit breaker
1) Insert the heating element in the threaded opening located on the bottom part
of the radiator.
2) Securely fasten the electric resistance to the body of the towel radiator with
a 22mm wrench.
3) The special sheath ensures a secure mounting and eventually allows a slight
supplemental torsion to perfectly align the thermostat with the radiator.
4) Tilt the radiator as in fig. 3, making sure that the opening on top of the
radiator is located on the highest side. WARNING. Do not lean the radiator on
the electronic control!
5) Fill the radiator with the specific liquid.
Llenar el radiador con el liquido específico (glicol)
6) Put the radiator back in vertical position and check the internal level of the
liquid (fig. 4).
7) Ensure a proper fastening of the heating element in the radiator.
8) Connect the device to mains and start heating (the top opening of the radiator
must remain open!).
9) Set the maximal temperature and check the level of the internal liquid. Due to
thermal expansion the liquid could brim over the radiator.
10) Remove the exceeding liquid (be careful to avoid burns!) in order to keep the
thermostat dry and avoid the liquid reaching the border. When the level of the
liquid stops growing wait for additional 5 minutes then stop heating.
11) If necessary, top up the radiator before the liquid cools down (keep the
temperature of the internal liquid checked all the time).
12) Close the top opening of the radiator with the appropriate cap.
13) Hook the radiator to the wall.
14) Connect the device to the mains. For models having no plug it is necessary
to install a suitable omnipolar disconnection switch ensuring complete
disconnection in case of category III overvoltage (that means a switch with at
least 3 mm of space between open contacts).
14
Installation Guide.