Multi Variable Air Conditioners Wall Mounted Type Indoor Unit
GMV-N56G/A3A-K, GMV-N56G/A2A-K
GMV-N56G/A4A-K, GMV-N56G/A8A-K
GMV-N56G/C9A-K, GMV-N56G/E3A-K
GMV-N63G/A3A-K, GMV-N63G/A2A-K
GMV-N63G/A4A-K, GMV-N63G/A8A-K
GMV-N63G/C9A-K, GMV-N63G/E3A-K
GMV-N71G/A3A-K, GMV-N71G/A2A-K
GMV-N71G/A4A-K, GMV-N71G/A8A-K
GMV-N71G/C9A-K, GMV-N71G/E3A-K
Model
GMV-N22G/A3A-D, GMV-N22G/A2A-D
GMV-N22G/A4A-D, GMV-N22G/A8A-D
GMV-N22G/C9A-D, GMV-N22G/E3A-D
GMV-N28G/A3A-D, GMV-N28G/A2A-D
GMV-N28G/A4A-D, GMV-N28G/A8A-D
GMV-N28G/C9A-D, GMV-N28G/E3A-D
GMV-N36G/A3A-D, GMV-N36G/A2A-D
GMV-N36G/A4A-D, GMV-N36G/A8A-D
GMV-N36G/C9A-D, GMV-N36G/E3A-D
GMV-N45G/A3A-D, GMV-N45G/A2A-D
GMV-N45G/A4A-D, GMV-N45G/A8A-D
GMV-N45G/C9A-D, GMV-N45G/E3A-D
GMV-N50G/A3A-D, GMV-N50G/A2A-D
GMV-N50G/A4A-D, GMV-N50G/A8A-D
GMV-N50G/C9A-D, GMV-N50G/E3A-D
GMV-N56G/A3A-D, GMV-N56G/A2A-D
GMV-N56G/A4A-D, GMV-N56G/A8A-D
GMV-N56G/C9A-D, GMV-N56G/E3A-D
GMV-N63G/A3A-D, GMV-N63G/A2A-D
GMV-N63G/A4A-D, GMV-N63G/A8A-D
GMV-N63G/C9A-D, GMV-N63G/E3A-D
GMV-N71G/A3A-D, GMV-N71G/A2A-D
GMV-N71G/A4A-D, GMV-N71G/A8A-D
GMV-N71G/C9A-D, GMV-N71G/E3A-D
Notes:
① Use copper wire only as unit's power cord. Operating temperature should be within its
rated value.
② If the power cord is more than 15m long, please increase properly the sectional area of
power cord to avoid overload, which may cause accident.
③ Above selection requirements: Power cord size is based on BV single-core wire (2~4pc) at
40°Cambient temperature when laying across plastic pipe. Air switch is D type and used at 40°C.
If actual installation condition varies, please lower the capacity appropriately according to the
specifications of power cord and air switch provided by manufacturer.
④ If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a hazard.
⑤Install cut-off device near the unit. The minimum distance between each stage of cut-off
device should be 3mm(The same for both indoor unit and outdoor unit).
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
220-240V ~ 50Hz
6
220-240V ~ 50Hz
6
220-240V ~ 50Hz
6
Air Switch
Power Cord Size
apacity
208~230V ~ 60Hz
208~230V ~ 60Hz
208~230V ~ 60Hz
208~230V ~ 60Hz
208~230V ~ 60Hz
208~230V ~ 60Hz
208~230V ~ 60Hz
208~230V ~ 60Hz
6
1
1
1
Minimum
Minimum Sectional
Sectional Area
of Ground
(A)
2
Wire(mm
)
6
1
6
1
6
1
6
1
6
1
6
1
6
1
6
1
1
1
1
Area of Power
2
Cord(mm
)
1
1
1
1
1
1
1
1