Display
For the first power-on, the display screen (including the key light) will be displayed in
full for 3s, and then the gear in the middle displays the state of running.
Display of normal running.
On the occurrence of a failure, the corresponding LED light will give a combined
display of failure code (loop display);
Where there is no failure, the LED light will display the current running gear of the
refrigerator.
Gear setting
The gear will be changed once every time when you press the key SET. Then, the
refrigerator will run under the setting value after 15s.
Fast cool function
Enter: Circulating modulation rapid cooling mode.
Operate: Indicator of rapid cooling lights up, and the refrigerator operates at
2ºC.
Exit: 1. Operate 150min under the rapid cooling mode.
2.Temperature adjustment can exit from the rapid cooling mode.
 Temperature control of freezing chamber
The freezing temperature is relatively low in "COLDER" position, while the freezing
temperature is relatively high in "COLD" position, thus, "NORMAL" position is
generally used.
When ambient temperature is high in summer, the temperature shall be in the
range from "NORMAL" to "COLD". If the ambient temperature is below 35ºC, then
"COLD" position shall prevail.
When ambient temperature is low in winter, the temperature shall be in the range
from "NORMAL" to "COLDER". If the ambient temperature is below 10ºC, then
"COLDER" position shall prevail.