Installation manual
Daikin room air conditioner
FTXP50M2V1B
FTXP60M2V1B
FTXP71M2V1B
FTXF20A2V1B
FTXF25A2V1B
FTXF35A2V1B
FTXF50A2V1B
Installation manual
FTXF60A2V1B
English
Daikin room air conditioner
FTXF71A2V1B

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Daikin FTXP50M2V1B

  • Página 1 Installation manual Daikin room air conditioner FTXP50M2V1B FTXP60M2V1B FTXP71M2V1B FTXF20A2V1B FTXF25A2V1B FTXF35A2V1B FTXF50A2V1B Installation manual FTXF60A2V1B English Daikin room air conditioner FTXF71A2V1B...
  • Página 2 3P511700-8C...
  • Página 3 3P511700-2A...
  • Página 4 3P511700-3A...
  • Página 5 3P511700-7B...
  • Página 6: Tabla De Contenido

    To remove the front grille ..........Daikin website (publicly accessible). 5.1.4 To re-install the front grille .......... ▪ The full set of latest technical data is available on the Daikin 5.1.5 To remove the electrical wiring box cover....extranet (authentication required).
  • Página 7: Preparation

    3 Disconnect the front panel shaft on the other side in the same 3 Install the air filter and then mount the front panel. manner. FTXP50~71M2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-7H – 2018.09...
  • Página 8: To Remove The Electrical Wiring Box Cover

    5 To re-install the cover, first hook the bottom tab onto the plate pocket. electrical wiring box, and slide the cover into the 2 upper tabs. Class 20~35: 116.5 (mm) Installation manual FTXP50~71M2V1B + FTXF20~71A2V1B Daikin room air conditioner 3P512025-7H – 2018.09...
  • Página 9: To Drill A Wall Hole

    ▪ Pipe length. Keep drain piping as short as possible. ▪ Pipe size. If drain hose extension or embedded drain piping is required, use appropriate parts that match the hose front end. FTXP50~71M2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-7H – 2018.09...
  • Página 10 1 Attach the drain hose with adhesive vinyl tape to the bottom of the refrigerant pipes. 2 Wrap the drain hose and the refrigerant pipes together using insulation tape. Left-side piping Left-back piping Left-bottom piping Installation manual FTXP50~71M2V1B + FTXF20~71A2V1B Daikin room air conditioner 3P512025-7H – 2018.09...
  • Página 11: To Check For Water Leaks

    10 Shape the wires so that the service cover fits securely, then close the service cover. FTXP50~71M2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-7H – 2018.09...
  • Página 12: Finishing The Indoor Unit Installation

    There are NO missing phases or reversed phases. The refrigerant pipes (gas and liquid) are thermally insulated. Drainage Make sure drainage flows smoothly. Possible consequence: Condensate water might drip. Installation manual FTXP50~71M2V1B + FTXF20~71A2V1B Daikin room air conditioner 3P512025-7H – 2018.09...
  • Página 13: To Perform A Test Run

    Result: Test run operation will stop automatically after about 30 minutes. 6 To stop operation, press For FTXF units 7 Press to switch the system on. 8 Press the centre of , and simultaneously. 9 Press twice. FTXP50~71M2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-7H – 2018.09...
  • Página 14: Technical Data

    8 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin extranet (authentication required). Wiring diagram Unified Wiring Diagram Legend For applied parts and numbering, refer to the wiring diagram on the unit.
  • Página 16 3P512025-7H 2018.09...