Terminals; Programming; Master Password Programming Procedure - Urmet 1723/46 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

6
If products 1723/11-/12 or 1784/1-/2 or
1784/3-/4, 1723/48 and 1723/46 are installed
on the single row, the arrangement shown in
the following drawing must be respected.

TERMINALS

+~
Power positive (12Vac or 12Vdc)
-~
Power negative (12Vac or 12Vdc)
H
Time input
A2
Relay 2 hall door release button
A1
Relay 1 hall door release button
S3
Normally open contact relay 1
S2
Normally closed contact relay 1
S1
Common contact relay 1
S6
Normally open contact relay 2
S5
Normally closed contact relay 2
S4
Common contact relay 2
GND
Ground

PROGRAMMING

MASTER PASSWORD PROGRAMMING PROCEDURE

The master password is required to access device confi guration programming mode.
Power the device.
Press the programming switch next to the terminal board 3 times in 5 seconds.
The device generates 3 confi rmation beeps and the button
Enter the password code (from 3 to 8 digits).
Press
to confi rm.
The device will beep 3 times to confi rm. The button
normal operation.
To modify the master password, if required, disconnect the device from the power supply for at
least fi ve seconds and repeat the procedure described above.