Timer Function - King gates ELEVO Serie Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 70
LAMP
24Vdc - 15W
+Vdc
(Functional Test)
PHOTO
0V
STOP
START
24Vdc
EDGE
24Vdc
LOCK
1 - 2
Flashing light: 24Vdc max. 15W
3
Phototest: 24Vdc output for safety devices testing
S2 Photo: Input for safety devices, normally closed
4
contact. Function associated to dip switch Func
0 VDC: Negative terminal for accessories devices
5
connected
6
Stop: normally closed contact
7
Start: normally open contact
24 VDC: Power supply 24Vdc (max. 10W)
8 - 10
Positive terminal for inputs and accessories
S1 Edge: Input for safety edges, normally closed
contact. Brief movement inversion in case of obstacle
9
during closing and block of the movement during
opening, movement block in case of obstacle in
opening
Lock / AUX: Default: electric lock 12V max.15W (for
11 - 12
courtesy light enable, see par. 13.
Antenna ground (13)
13 - 14
Antenna signal (14)
NOTE: the electric lock is a non-mandatory accessory
m
TIMER FUNCTION: if START contact is kept closed
ANT
(for instance through a timer-controlled or bistable relay),
control unit opens the door and leaves the door opened.
The automation does not accept closing commands (neither
automatic nor wired) until START contact is reopened.
In this mode, dip switch 1 STEP is set to OFF and dip 2 AUTO
to ON to ensure that the gate never remains locked open.
m
13 14
If START contact is kept closed during the control unit
starting after a blackout, the door will immediately execute
the start command.
m
CAUTION!
-
Never cut or remove the cable supplied with ELEVO.
-
If not already available, a power socket for connecting
ELEVO to the mains must be made by qualified and
experienced personnel in strict observance of current
legislation, standards and regulations.
ELEVO must be connected to the supply mains by a
qualified electrician.
-
To test ELEVO, just insert the plug into a power outlet,
using an extension cord if necessary
- 34 -
- 34 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elevo620Elevo1000

Tabla de contenido