simalube IMPULSE Manual Del Usuario Y Información Técnica página 19

Ocultar thumbs Ver también para IMPULSE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
Malfunctions
Red LEDs flash 4x
No lubrication!
App error message:
"pump blocked"
Red LEDs flash 5×
App warning: "Max.
pump strokes reached"
App connection error
Possible cause
Pump blocked due to
clogged line.
Pump is mechanically
blocked or defective.
When started: Max.
number of pump strokes
reached.
Connection errors can
happen for various
reasons.
19
IMPULSE
Measures
Remove IMPULSE with the
dispenser screwed on.
Check lubrication point and
purge. Screw on IMPULSE
with dispenser again.
Change dispenser (see
p. 17, ch. 7, pt. 1−3).
Check and lubricate the
lubrication point.
Fit IMPULSE (see p. 15,
ch. 4, from pt. 6).
Replace the device.
Replace IMPULSE.
Try to connect with the
IMPULSE again.
Check if you are in range
of the IMPULSE.
Check if your Bluetooth
is turned on for the
smartphone.
®

Publicidad

Tabla de contenido
loading

Tabla de contenido