Rheem® offers thermostatic, thermostatic with an integrated mixing valve, and non-thermostatic tankless electric water heaters.
To obtain optimum performance and energy savings, the water heater should be located as close as possible to the point-of-use. The
unit is supplied with compression rings and nuts suitable for direct coupling to 3/8" copper or PEX™ piping. Do not use additional
screwed fittings, pipe dope or teflon tape – doing so will void the warranty. DO NOT SOLDER PIPES WHILE THE UNIT IS INSTALLED as
serious damage to the heater will result and the warranty will be voided.
Thermostatic Tankless Electric Water Heaters™, are designed to accept cold or preheated water and heat it to temperatures suitable
for normal domestic usage up to a maximum temperature setpoint of 140°F.
Thermostatic Tankless Electric Water Heaters with Integrated Mixing Valve™, are designed to take in cold water and heat it to
temperatures suitable for handwashing and other mild temperature uses up to a factory preset of 105°F. The heaters are also
equipped with an ASSE 1070-2004 approved mixing valve to meet UPC 407.3 and similar plumbing codes for public handwashing
applications.
Non-thermostatic Tankless Electric Water Heaters™, are designed to take in cold water and heat it to temperatures suitable for
handwashing and other fixed-flow applications.
THIS HEATER MUST BE INSTALLED IN A LOCATION WHERE IT IS NOT SUBJECT TO FREEZING
TEMPERATURES.
The heater should be mounted on the wall under the sink, as close to the point-of-use as possible. Ideal position is fittings
pointed down; however, the heater may be mounted in any orientation.
Note: a logo decal has been provided to ensure branding is clearly displayed in any mounting orientation.
Make sure to leave a minimum of 8 inches service clearance at
the end OPPOSITE the fittings.
Manufacturer's National Service Department | 400 Captain Neville Dr. Waterbury, CT 06705
Eemax® 800-543-6163 | EcoSmart® 877-474-6473 | Rheem® or Richmond® 800-374-8806
Information contained in this document is subject to change without notice.
GENERAL
MOUNTING THE UNIT TO THE WALL