Presto 29007 Manual De Instrucciones página 4

Tabla de contenido

Publicidad

ENGLISH
1) INSTALLATION INSTRUCTIONS
2) On line thermostatic safety regulator G1/2" Part no. 29006
3) PRECAUTIONS FOR USE (The product guarantee depends on the respect for these rules)
INSTALLATION and START UP
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully drain
the pipes that can damage the mechanisms or water passages (PRESTO® heads that can be dismantled from front).
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water.
Abrasive, acid, alkaline or ammonia-based household products are prohibited.
MAINTENANCE
Never lubricate the internal mechanism, particularly the caps and valve seals.
4) Lever set screw
5) Adjusting lever
6) Built-in non-return check valves
7) GENERAL INFORMATION:
Thermostatic regulator delivers a flow rate of 26L/min. for 1 bar of pressure loss.
Allows for simultaneous supply of up to 5 washbasins or 2 shower taps (depending on their flow rate)
Instantaneous shut-off of the hot water supply in case of accidental shut-off of the cold water.
This regulator is equipped with built-in non-return check valves at the inlet.
Regulator preset at 38°C (+/- 1°C), balanced pressu re at 3 bars.
Anti-scald security, in accordance with the EN1111 standard
OPERATING CONDITIONS:
- Recommended dynamic pressure: 2 to 5 bars.
- Max static pressure: 10 bar
- Max hot water inlet temperature: 85° C
- Min temperature difference between hot water and lukewarm water: 15°C
- Mixed Temperature Stability
- Max dynamic pressure difference between hot and cold water: 1 bar
- Minimum lukewarm water flow rate: 6L/min.
- Lukewarm water flow rate at 3 bars: 47L/min.
FLOW CURVE:
8) Flow rate
9) Head loss
10) INSTALLATION DIAGRAM
11) Hot water
Cold water
Lukewarm water
12) Hot water production
13) Shut-off valve
14) Safety unit
15) Filter
16) Draining
17) INSTALLATION:
- The installation must be done in accordance with current regulations by a qualified person.
- Installation of 2 filter seals at the inlet of the body (provided) mandatory, helping to keep in place, the non-
return valves in the regulator
- This regulator operates in all positions.
- Connect the feeds by respecting the (C-H) and (F-C) markings and the colour bands.
- Adjust the desired temperature as indicated on the views below, verify it at the closest outlet
using a thermometer.
- It is dangerous to supply mixed water over 45° C.
MAINTENANCE:
- For a optimum working, we recommend a regular cleaning (at least every six months) of the moveable shuttle and
the water mixing chamber
- Verify the accuracy of the temperature displayed for a thermostat every year (+/-2° C).
- In case of an abnormally low flow or other, remove the regulator, and clean the inlet filter seals.
- If the problem persists, replace the regulator.
18) Unscrew the lever set screw by at least 5 turns
19) Pull the lever to unlock it by rotation
20) Adjust the desired temperature
21) Push the lever to lock the new setting and retighten the lever set screw.
22) Installation of 2 filter seals at the inlet (provided) mandatory.
23) This document is not contractual; we reserve the right to modify the characteristics of our products
without notice.
24) PATENTED and REGISTERED MODELS
4
: +/- 2° C
from 37 to 42°C for a flow range from 12 to 47L/mn

Publicidad

Tabla de contenido
loading

Tabla de contenido