Installation requirements
Special gas requirements (Gas models sold in Massachusetts)
Commonwealth of Massachusetts requirements:
WARNING
Gas leaks may occur in your system, creating a dangerous situation.
•
Gas leaks may not be detected by smell alone.
•
Gas suppliers recommend you purchase and install a UL-approved
gas detector. Gas detector should be installed in accordance with the
manufacturers instructions.
•
Range must be installed by a qualified plumber or gas fitter by the State of
Massachusetts.
•
A T-handle manual gas valve MUST be installed in the gas supply line to
your range.
•
If a flexible gas connector is used to install your range, multiple flexible gas
lines must not be connected in series.
Install_NX58H56_DG68-00524A-13_EN+MES+CFR.indb 19
Install_NX58H56_DG68-00524A-13_EN+MES+CFR.indb 19
Electrical requirements
WARNING
To reduce the risk of fire, electric shock, or personal injury:
All ranges
•
Do not use an extension cord or adapter plug with this range.
•
This range must be properly grounded.
•
Check with a qualified electrician if you are in doubt as to whether your range
is properly grounded.
•
Do not modify the plug provided with your range—if it doesn¡¯t fit the outlet,
have a proper outlet installed by a qualified electrician.
•
All wiring and grounding must be done in accordance with local codes or, in
the absence of local codes, with the National Electrical Code, ANSI/NFPA No.
70 – Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 –
Latest Revisions and local codes and ordinances.
•
Wiring diagram is located on the back of the range. (Inside of the cover back
wire)
•
This range is equipped with an electronic ignition system that will not operate
if plugged into an outlet that is not properly polarized.
Gas models
•
All gas models are equipped with a power cord with an equipment-grounding
conductor and a grounding plug.
•
A 120-Volt, 60-Hz, AC, approved electrical service with or 20-amp circuit
breaker or time-delay fuse is required for all U.S. and Canadian models.
•
Check for ¾" (1.9 cm) UL-listed strain relief where the power cord comes out
of the range cabinet.
•
Do not reuse a power supply cord from an old range or other appliance.
•
The power cord electric supply wiring must be retained at the range cabinet
with a suitable UL-listed strain relief.
•
A time-delay fuse or circuit breaker is also recommended.