Water quality

The water quality must be within the following limits
Chlorine concentration less than 2.5 ppm
pH level from 6.9 to 8
In case of strong shock treatment, isolate the appliance using the downstream and upstream valves of the by-pass
system. Once the treatment has finished, set the by-pass valves to their initial position prior to the treatment.
VERY IMPORTANT: the warranty will be invalidated if chemical concentration levels are not maintained within the
limits mentioned.
Never make the injection of chemicals (chlorine, acid, etc.) directly in the filtration pump strainer.
It could be a highly corrosive product that would irreversibly destroy your appliance.

Maintenance (by a qualified technician)

Before any maintenance operation, the heat pump must be completely stopped for few minutes before connecting
pressure controllers. This is because high pressure and temperature inside the heat pump could be harmful.
Please check the following on a monthly basis:
Check and clean the evaporator (with a soft brush or water jet).
Do not use high pressure cleaner.
Check all electrical and ground connections.
Check that all electrical connections and terminals are securely connected.
Check gas pressure (when heat pump is stopped, manometer must indicate a pressure higher than 0.5)
Please check the following points yearly:
Check settings.
Check all electrical connections and ground.
Check condenser (water tank) cleanliness.
Use soft soap and water to clean the heat pump casing.
Do not use solvents.

After Sales Technical Service

In case of technical problems regarding any of the heat pumps, the following measures should be taken:
Provide to the technical service the following essential information:
Serial number of the machine
The value and pictograms displayed on digital controller.
The value of programmed settings
If fan is working or not
Contact your dealer and pass on this information together with the dimensions of the swimming pool, your personal
details (address, telephone number) and the description of the failure.
If this procedure is respected, the technician will be able to make as accurate diagnostic of the failure.
The recommended solution will be implemented briefly after that.
IMPORTANT: If this measure is not followed, warranty will be cancelled.
Contains fluorinated greenhouse gases covered by the Kyoto protocol in a hermetically sealed circuit:
-
R32:
At the end of product lifetime, it must imperatively be entrusted to a qualified professional (refrigeration technician) in
order to dismantle it in accordance with the laws in force (recovery of cooling gas, of metallic materials which can be
recycled...).