Care and service
DANGER
Inadvertently starting up device
Risk of injury, electric shock
Turn the program switch to the "OFF" position.
Remove the Intelligent Key prior to all work on the device.
Pull out the charger mains plug.
Unplug the battery connector.
Drain and dispose of the waste water and fresh water.
Maintenance intervals
Each time after use
ATTENTION
Incorrect cleaning
Risk of damage.
Do not spray the device with water.
Do not use aggressive detergents.
A detailed description of the individual maintenance work
is provided in the chapter "Maintenance Work".
Drain the waste water.
Rinse the waste water tank with clear water.
Clean the coarse dirt sieve.
Only with R cleaning head: Remove the coarse dirt con-
tainer and empty it.
Clean the exterior of the device using a damp cloth, wet-
ted with a mild washing lye.
Check the suction lips, check for wear and tear and re-
place if necessary.
Clean the squeegee blades, check for wear and tear
and replace if necessary.
Clean the brushes, check for wear and tear and replace
if necessary.
Charge the battery.
If the charging state of the battery is below 50%,
charge the battery fully and without interruption.
If the charging state of the battery is above 50%, only
recharge the battery if the entire operating duration
will be required when next used.
When used regularly, charge the battery fully and with-
out interruption at least once a week.
A detailed description of the individual maintenance work
is provided in the chapter "Maintenance Work".
If the device is temporarily shut down: Perform equaliza-
tion charging of the battery.
Check battery poles for oxidation, brush off if necessary.
Make sure the connection cables are firmly in place.
Clean the seals between the waste water tank and the
cover, check for leaks and replace if necessary.
Drain the fresh water tank and flush out deposits.
Clean the fresh water filter.
Check the acid density of the cells if the batteries are not
maintenance-free.
Only with R cleaning head: Clean the brush tunnel.
Only with R cleaning head: Clean the water distribution
strip on the cleaning head.
For a longer downtime, shut down the device when the
battery is fully charged. Fully charge the battery at least
once a month.
Weekly
Monthly
Have the prescribed inspection performed by Customer
Service.
Safety inspection/maintenance contract
You can agree on regular safety inspections or close a
maintenance contract with your dealer. Please seek advice
on this.
Turn or replace suction lips
If the suction lips are worn, they must be turned over or re-
placed.
The suction lips can be turned 3 times until all 4 edges are
worn.
1. Remove the suction bar.
2. Unscrew the star handles.
Star grip
1
Tension band
2
Inner part suction bar
3
Tension lock
4
3. Pull out the inner part of the suction bar.
4. Open the tension lock.
5. Remove the tension band.
6. Detach the suction lips from the inner part.
Squeegee blade
1
Support lip
2
Inner part suction bar
3
Tension band
4
7. Press the turned or new suction lips onto the nubs of the
inner part of the suction bar.
8. Attach the tension band.
9. Push the inner part of the suction bar into the upper part.
10.Screw in and tighten the star handles.
English
Annually
Maintenance work
19