^ 8.2 Make the connections for the dispenser pumps and empty indicators, as well as the
individual black (sw), blue (bl) and green-yellow (gnge) wires in accordance with the wiring
plan.
Wiring plan DOS-FKE-01 for WS 5071, W 6071.
Wiring plan DOS-FKE-02/03/04 for WS 5101, WS 5141, WS 5191, WS 5240, WS 5320,
WS 5243, WS 5323.
^ 8.3 Fit the dispenser pump (Fig. 4).
^ 8.4 Fit the pump housing lid in position and secure it with 3 self-tapping screws.
9. (Optional) Fitting the housing on the mobile stand
^ 9.1 Secure the housing to the stand with 4 M5 raised head screws (Fig. 5).
^ 9.2 Secure the tube holder to the stand with pop rivets (Fig. 5).
^ 9.3 If required, clip the overflow connection (for hose leaks) in the hole in the pump lid.
^ 10. Pass the connection cables 8 x 0.5 (1) and 6 x 0.5 (2) through the screw connectors
PG 13.5 (WS 5071, W 6071 Fig. 6, WS 5101, WS 5141 Fig. 7) in the connection strip to the
EZL 112 electronic unit (WS 5071, W 6071, WS 5101, 5141 Fig. 8) and fit a clip (3) on the
screening.
11. Fitting the electronic unit
^ 11.1 Connect the 8-pole ribbon cable to the transformer-rectifier unit EG 110.
Connect the EZL 112 electronic module via the green terminal strip with the connection wires
in accordance with the wiring plan.
Make bridge connections on the 17-pole terminal strip with black (sw) wires for empty
indicators that are not in use.
Wiring plan DOS-FKE-01 for WS 5071, W 6071.
Wiring plan DOS-FKE-02/03/04 for WS 5101, WS 5141, WS 5191, WS 5240, WS 5320,
WS 5243, WS 5323.
Note:
The 6 x 0.5 cable for the empty indicators must not be laid next to any mains cables! The
screening must be secured with a clip!
For safety reasons the length of the connection cables must not exceed 4.50 m!
All unused terminal screws must be tightened to prevent them working loose during operation!
Wire colours:
bl
Blue
br Brown
gn Green
ge Yellow
rt
Red
sw Black
ws White
M.-Nr. 05 648 960/01