9800 Ozone Sanitizer
EN

IMPORTANT SAFETY INSTRUCTIONS

• Read this instruction manual carefully before you start using 4CR Ozone Sanitizer.
• Use 4CR Ozone Sanitizer in strict accordance with the instructions described in this operation
manual.
• Ensure that the power outlet is protected by an automatic circuit breaker and has a reliable,
independent ground connection.
• To prevent the risk of electric shock, always turn the power switch (1) to the off position
before using the device, as well as at the end of the work.
• Do not use 4CR Ozone Sanitizer if the air temperature in a room to be treated is above 38 °C
or humidity is above 90 %.
• It is forbidden for anyone to be in the room where 4CR Ozone Sanitizer is working,
because ozone concentration can exceed the maximum permissible level and exert a
negative impact on human health.
• Avoid eye contact with the UV radiation produced by the device as it can burn your eyes.
• Avoid ingress of any objects into the vents of the device.
• Do not store or use the device outdoors. The device is intended for indoor use only.
• Do not block any ventilation openings while the unit is operating as this may cause damage
to the device.
• Store 4CR Ozone Sanitizer in a dry, dust free place.
• Never disassemble 4CR Ozone Sanitizer.
• Never operate the device with wet hands, as well as in high humidity and damp conditions.
• Never use 4CR Ozone Sanitizer near flammable liquids and in a dusty environment.
• 4CR Ozone disinfector is meant for professional use only.
PURPOSE
4CR Ozone Sanitizer is designed to clean and disinfect air, surfaces and parts of cars, vans, trucks
and trailers, as well as premises up to 50 m3 from unpleasant odors, viruses, bacteria, mold,
fungi, allergens through the generation of ozone and subsequent accelerated decomposition
of ozone into oxygen.
4CR Ozone Sanitizer - fully automatic device. The operator only needs to select one of the
three programs and press the START (10) button to start the program and begin the processing
of the room. 4CR Ozone Sanitizer uses a corona discharge device to produce the amount of
ozone needed to treat the room.
When the air temperature in the room to be treated is above 38°C, ozone generation is
not physically possible. In this case, before ozone treatment, it is necessary to lower the
temperature by turning on the air conditioner.
After the ozone treatment is completed, the device automatically switches to the mode of
converting residual ozone into oxygen by exposing the air with UV radiation of a certain
wavelength.
The red indicator (11) indicates that ozone is being produced, or a UV lamp is on.