TROUBLESHOOTING
IF THE FILL VALVE:
• DOES NOT TURN ON
• WON'T TURN OFF
• WON'T REFILL TANK
REMOVE CAP AND CHECK FOR DEBRIS
A:
Turn off water supply.
B:
Flush toilet.
C:
With right hand push float up, grip and
hold shaft under float.
D:
With left hand twist cap and lever arm
counterclockwise to unlock cap. Let
cap hang on float cup.
E:
Hold empty cup upside down over
uncapped valve to prevent splashing.
F:
Turn water supply on and off a few
times.
G:
Turn water supply off.
H:
Replace valve cap.
• Place cap assembly on top of
gray valve body by aligning cap
arm and adjustment rod next to
refill tube.
• Press down on top cap while
rotating top & arm clockwise
to locked position.
See Our Troubleshooting
HOW-TO VIDEO
VIDEO
http://bit.ly/2yAdZn7
14
REPLACE FILL VALVE SEAL
A:
Remove cap (see page 12).
B:
Replace seal with a
Fluidmaster 242 Seal.
C:
Replace valve cap.
• Place cap assembly on top of gray valve body by
aligning cap arm and adjustment rod next to refill tube.
• Press down on top cap while rotating top & arm clockwise to locked position.
TURN
*
Always use genuine Fluidmaster parts when installing or repairing. Fluidmaster will not be
COUNTER-
responsible or liable for use of non-Fluidmaster parts during installation or repair.
CLOCKWISE
WATER LEVEL IN BOWL IS TOO LOW
A:
WATER FROM REFILL TUBE MUST
FLOW THROUGH OVERFLOW PIPE
Make sure the refill tube is supplying water down
overflow pipe. (Metal side out for refill clip)
B:
WATER LEVEL IN TANK MAY BE TOO LOW
1/2" below top of overflow pipe is recommended
(see page 10).
C:
FLAPPER MAY BE CLOSING TOO SOON
Give flapper chain approximately 1/2" of slack.
(small "j" shape)
D:
ROLLER CLAMP MAY NEED TO BE
ADJUSTED
*
genuine
(see page 12).
Cap
Seal
Refill Tube
Overflow
Pipe
1/2"
Overflow
Pipe
0
8
15