Sprint Quick Operation Guide - Description of Parts and Controls of Equipment
Before using the equipment, please read the User Manual Dental Line carefully.
The purpose of this guide is to identify commands, parts, and instruments that may be available to the equipment, including optional items.
This guide does not define the equipment configuration that may vary according to the customer's request.
In case of loss of the User Manual and/or Operation Guide, please contact us by e-mail
Before Turning On the Equipment:
1 -
2 -
1º - Check if the equipment is properly installed in accordance
with the instructions in chapter 6 of the User
Manual Dental Line;
1
2º - Turn On the air compressor that supplies the equipment;
2
3º - Open the main water supply valve of the equipment;
4º - Turn On the equipment's power circuit breaker.
Turning On the Equipment:
1 -
2
2 -
1º - Turn On the On/Off switch;
1
2º - Activate the "Seat Up" command on the chair base until the
seat reaches its maximum height limit;
3º - Close the pressure valve;
4º - Remove the water tank and make sure it filled with water. If necessary, fill it with drinkable water
up to the limit indicated in tank and reattach it again. If you wish, to place prophylactic products (low
concentration);
5 º - Open the pressure valve and check if the water tank is well attached and free of leaks;
6º - Before starting the use equipment, verify the operation of all instruments and commands
available and perform the cleaning and sterilization of the instruments (chapter 7 of the User
Manual Dental Line - Cleaning and Disinfection).
10
9
8
7
Observe the Scheduled Review system for your equipment - Chapter 12 of the User Manual Dental Line.
Water Tank
Pressure Valves
On/Off Switch with LED Indicator
Fuse Holder
1 -
Zero Position
1
2 -
Work Position
3 -
Backrest Up ( )
4 -
Seat Down ( )
2
5 -
Backrest Down ( )
6 -
Seat Up ( )
3
7 -
On/Off Operating Light
8 -
Spittoon Bowl Flush
4
9 -
On/Off Vórtice Saliva Ejector
10 -
Progressive/Activation Pedal
5
6
F03
export3@olsen.odo.br
informing the serial number of your equipment.
5
12
2
1
4
3
11
6
7
To save a work position:
1º - Press the Zero Position button;
2º - Adjust the backrest to the desired position;
3º - Adjust the seat to the desired position;
4º - Press the Work Position button for 5 seconds. The equipment will emit 2 long beeps;
5º - Press command 1 (Seat Up) while the equipment beeps; The equipment will emit 2 short beeps to
confirm the procedure;
6º - Press the Zero Position button.
Evolution Plus
LED Premium
1
Concept Plus
2
3
your hand in front of the sensor (3) or hold the control rod (2), in the case of Concept Plus or turn the control
knob (1), in the case of the Premium LED Operating Light.
1 -
Seat Up/Position 1
2 -
Backrest Up/Position 2
8
3 -
Seat Down/Position 3
4 -
Backrest Down/Spit Position
5 -
Work Position
6 -
Zero Position
9
7 -
Progressive/Activation Pedal
8 -
Cup Filler
9 -
On/Off Vórtice Saliva Ejector
10 -
On/Off Operating Light
11 -
Spittoon Bowl Flush
10
12 -
Metal Handle
1 -
Control Knob
2 -
Control Rod
3 -
Sensor
1° - To activate the Operating Light, press the
Operating Light On/Off button at the base of the
chair (section Commands - 7), this action also
enables the sensor (3) and the control button/
3
rod (2);
2° - To change the lighting intensity of the
Evolution Plus Operating Light, keep the
command button - Commands section (7) -
pressed for more than 2 seconds;
3° - To turn on or off the Concept Plus and LED
Premium Operating Light, pass your hand in
front of the sensor (3) at approximately 5 cm
distance or hold the control rod (2), in the case of
Concept Plus, or turn the control button (1), in the
case of the Premium LED spotlight;
4° - To change the lighting intensity of the
Concep Plus and Premium LED reflectors, keep
Page 01 - 5403132 - R04
- Equipments made to last!