CTEK D250S DUAL Manual Del Usuario página 21

Ocultar thumbs Ver también para D250S DUAL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONNECTING AC/DC ChARGERS
SITUATION
230/110 V charger for the Service and
Starter battery.
PROBLEM
The 230/110 V charger should charge
both the Service and the Starter bat-
tery, and be synchronized with all other
energy sources.
INSTALLATION ShEET 6
SOLUTION
The single output 230/110 V charger is
connected directly to the Service bat-
tery. The Starter battery is pulse charged
through the SMARTPASS, going back-
wards. The solar panel will also charge
the Starter battery backwards through
the SMARTPASS.
12V
RECOND
MODE
NORMAL
RECOND
NIGHT
+IN
12V
D250S DUAL
+IN
+OUT
+IN
+OUT
12V
SMARTPASS
+OUT
TIP 6
See Tip 1, Tip 2, Tip 4 and Tip 5
The battery cables of the 230/110 V
charger are connected directly to the
Service battery.
WARNING!
•Max 22 V input
•Do not connect two solar
panels in series
 EN • 21

Publicidad

Tabla de contenido
loading

Tabla de contenido