Defects - Malfunctions - LaCimbali M100 GT Manual De Uso E Instalación

Dosatron
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 163

23. Defects - Malfunctions

Direct action by the customer
Before calling service personnel, to avoid unnecessary expense, check whether the machine problem corresponds to
one of the cases listed below.
PROBLEM
The coffee machine does not work
and the display (Ts) is blank.
Leaking from the lter holder rim (11). Underpan gasket dirty with coffee.
Coffee dispensing time too short.
Coffee drips out of machine.
Loss of water under the machine.
Machine heated up, but it does not
dispense coffee.
The automatic level-control devices
remain in operation.
MESSAGE
POSSIBLE CAUSES: when the message is
visualized
Machine cold
This message will appear on the display if any
Please wait
dispensing icon is pressed every time the machine
is turned on until the service boiler pressure falls
below the pre-set working pressure.
Service
This message is displayed when the machine
needed
requires the
In order to eliminate temporary the message, press
the icon
and press the icon
message:
The message will reappears in the successive
relighting of the machine with the main switch.
CAUSE
No electricity supply.
Coffee ground too coarse .
Coffee too old.
Filter holes blocked or filter holder
(11) outlet hole dirty.
Coffee ground too ne.
Discharge well clogged up.
Discharge basin hole blocked.
Water supply or water softener tap
closed.
No water in system.
Same causes as above.
Messages in explicit mode
periodic maintenance intervention.
to access the programming menu:
CARRY OUT
MAINTENANCE
to cancel out the
37 EN
SOLUTION
Check the electricity supply.
Check the position of the main switch
(1).
Clean using the special brush provided.
Use a ner grind.
Use new coffee.
Clean.
Use a coarser grind.
Clean.
Clean.
Open the taps
Wait until water is available or call a
plumber.
Same solution as above.
VERIFICATIONS
When the service boiler reaches the pre-set
pressure, the message automatically disappears.
Contact the authorized technical department. The
message will be displayed until the service will be
carried out.
Note: the need to carry out maintenance is
recorded by the machine.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M100 hd

Tabla de contenido