ENGLISH
Frequency
Sensitivity: >8 V RMS, Maximum input: 600 V DC or 600 V AC RMS
Duty cycle
Pulse width: 0.1 ms - 100 ms
Frequency width: 5 Hz to 10 kHz
Sensitivity: >8 V RMS
Maximum input: 600 V AC RMS or 600 V DC
OTHER MEASUREMENT APPLICATIONS
• Diode test: Max. 1.5 mA, open-circuit voltage ~3.0 V DC
• Continuity check: Audible signal <50 Ω, test current <0.35 mA
• Sampling frequency: 3 samples per second
• Low impedance (Low Z): Input impedance: >3kΩ
• Auto power off: After ~30 minutes of inactivity
• Overload: 'OL' indicated on display, overload protection
1,000 V in Voltage setting, 600 V RMS in all other settings
• Polarity: '-' on the display indicates negative polarity
• Non-contact voltage detection: >90 V AC
• Display: 3-5/6 digit, 6,000 count LCD
To ensure safe operation and service of the meter, please follow these
instructions. Failure to observe these warnings can result in severe
injury or death.
• Before every use, verify meter operation by measuring a known
voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category-based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Use only with CAT III- or CAT IV-rated test leads.
• Ensure that meter leads are fully seated and keep fingers away from
the metal probe contacts when taking measurements.
• Use caution when working with voltages above 25 V AC RMS or
60 V DC. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electric shock, replace
batteries when a low-battery indicator appears.
• Do not attempt to measure resistance or continuity on a live circuit.
• Do not hold the meter above the hand and finger guard during use.
4
ELECTRICAL SPECIFICATIONS
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
500.0 kHz
0.1% - 99.9%
Max input: 600 V RMS
WARNINGS
0.001 Hz
0.01 Hz
0.1 Hz
±(1.0% + 5 digits)
1 Hz
10 Hz
100 Hz
±(1.2% + 2 digits)
0.10%