4. Simple learning functions (can also be done using a PC and the Velbuslink software)
In order to activate a relay output, push button(s) must be assigned (learned) to each relay output.
It is possible to learn up to 15 different push buttons for the same action and for each channel. The way an output will react on a push
button is determined by the way a push button is learned or by the setting of the channel rotary switches.
Here are some direct action learning functions, no timer can be used, channel rotary switches (7 and 8 on page 2 ) have no function:
ADDR. SWITCH SETTING
Ch.1
Ch.2
Ch.3
F1
F2
F3
E1
E2
E3
D1
D2
D3
EXAMPLE:
A push button must activate or deactivate relay output number 3 on each press (toggle).
Turn the switches in position "D 3" (mode LED 3 will blink fast, indicating learning is activated).
Press one by one the push buttons (for at least 2 sec) that need to activate this output .
To confirm, the corresponding output will be activated.
If you want only to turn ON using a specific button, then choose mode "E3" for output 3.
If you want only to turn OFF using a specific push button, then choose mode "F3" for output 3.
Combinations are possible, so a button can turn OFF output 1 but at same time turn ON output 3...
ALWAYS RETURN THE MODULE TO ITS DEDICATED ADDRESS TO EXIT THE LEARNING MODE.
Ch.4
[OFF] Push buttons switching OFF the relay of the selected channel
F4
E4
[ON ] Push buttons switching ON the relay of the selected channel
D4
[TGL] Push buttons switching the relay ON or OFF (toggle function)
Action mode description
ENGLISH
Ou t1
Out2
Out3
Ou t4
ADDR.
CH1
CH2
C H3
CH4
ON
R x Tx
Mod e1
Mode 2
Mode3
Mode4
5