OPERATION MODE
0
Start or stop a timed relay output, set time from TIME 1 table switches
1
Restartable relay output timer (Staircase ), set time from TIME 1 table switches
2
Non restartable relay output timer, set time from TIME 1 table switches
3
Turn OFF a relay output after a time (off delay), set time from TIME 1 table switches
4
Turn ON a relay output after a time (on delay), set time from TIME 1 table switches
5
Turn ON a relay output after button has been released, set time from TIME 1 table switches -
6
The relay output will blink at 1Hz rate during a time set from TIME 1 table switches
7
7 to F are special C-mode 2 timer actions.
8
A short press on the button will activate the relay output for a time set by TIME 1
9
switches. A long press (keep the button pressed) will activate the relay output
A
according to TIME 2 switch setting.
B
Example: If a button is learned with ADDR setting "C2", the upper CH2 switch is
C
set to "7", the lower CH2 switch to "8" . Then, a short press will activate relay 2
D
for 5 minutes, a long press will activate the output for 10 minutes.
E
F
CH1
CH2
ADDR.
TIME 2
-
-
-
-
-
-
5 minutes
10 minutes
15 minutes
30 minutes
1 hour
2 hours
5 hours
24 hours
ON / OFF
CH3
CH4
ENGLISH
TIME 1
0
Momentary
1
5 seconds
2
10 seconds
3
15 seconds
4
30 seconds
5
1 minute
6
2 minutes
7
5 minutes
8
10 minutes
9
15 minutes
A
30 minutes
B
1 hour
C
2 hours
D
5 hours
E
24 hours
F
ON/OFF
7