Loosen the flame pipe unit using the special tool
provided for TEHA oil burners. Place the tool on the
edge of the flame pipe unit and tap the flame pipe unit
off upwards. Hold on tight to the tool and do not let it fall
between the flame pipe unit and the burner housing.
-
Pull the flame pipe unit out upwards.
-
Clean the heating coil inside the burner using suitable
brushes and a vacuum cleaner. Ensure that you do not
damage the oxide ceramic disc on the bottom of the
combustion chamber.
-
Remove any residual soot from within the combustion
chamber using the vacuum cleaner.
-
Reassemble the burner in reverse order.