TECHNICAL SPECIFICATIONS:
Input:
Maximum power:
Maximum output current:
Power feeder mode output voltage:
Battery charge mode output voltage:
Supported battery capacity:
Charging voltage compensation
with battery temperature:
Protection level:
Weight
CONNECTIONS:
230 V input:
12 V output:
Temperature sensor and JP5 data line
connection:
JP9 tank level sensor connection:
PROTECTIONS:
Input fuse:
Input Overvoltage Protection:
Protection against reverse polarity:
Short-circuit protection:
Overload protection:
Output overvoltage protection:
Battery charge overtemperature protection:
Battery overtemperature protection:
REFRIGERATOR output fuse F1
AUX output fuse F2
12 V LINE output fuse F3
12 V LINE output fuse F4 - PUMP
EXTERNAL LIGHT output fuse F5
IMPORTANT INSTRUCTIONS:
- If the battery charger is not installed and used in
compliance with these instructions, it can damage or
cause injuries to the operator.
- The connection of the power feeder/battery charger
must be performed exclusively by specialised technical
personnel.
- Do not place the battery charger directly on or
under the charging battery, the battery gases or liquids
can corrode and damage the battery charger.
- Avoid recharging a frozen battery.
- In order to reduce the risk of injuries, charge only the
lead AGM or gel batteries (make sure that the selected
charging curve is adapted to the type of batteries to
recharge).
- Study all specific precautions of the battery
manufacturer such as the removal or not of the plugs of
the cells during charging and the recommended
charging parameters.
8
220-240V 50/60Hz 2.3A
CC: 14.4V TC(Voc): 14.4V VF: 13.8V
Compatible with the battery charger current
(please refer to the charging specifications of the battery)
(if connected to the NTC 10K@25 B3977 sensor)
AMP Mate-N-Lok connector
6.3 mm male faston terminal
Female MOLEX MINI-FIT JR 4 pole connector with male terminals
(use male MOLEX MINI-FIT JR with female terminals)
Female MODU2 6 pole connector with male terminals
(use male MODU2 with female terminals)
4A 250V delayed (internal fuse)
YES (if NTC 10K@25 B3977 sensor is connected)
- Do not connect the device with network voltages
different from the rated value.
- The surface of the battery charger can overheat
during charging and later.
- Do not perform changes to the device or to the
wiring of the battery charger.
- Do not try to open the battery charger. There is a risk
of electric shocks, even if the battery charger is
disconnected. Inside, there are not any components
that can be repaired by the user.
- The warranty is voided in case of an improper use
of the device and the manufacturer declines any
responsibility for damages to things or persons.
270W
19A
13.5V
SI
IP20
1.8Kg
SI
SI
SI
SI
SI
SI
30A
20A
15A
15A
5A