2. Tear the seal with pliers by pulling outward. (Fig. 6)
Fig. 6
3. Attach the rectangle damper properly. Fix rectangle
damper to the top by 4 screws (ST4x6mm). (Fig. 7)
NOTE: Damper must be verified that it closes properly.
4 screws (ST4x6mm)
Fig. 7
4. Use Duct Tape to ensure joint is sealed and air tight.
Rear Venting (horizontal) using rectangular damper.
1. Use pliers to find the seam from the edge of the rear
opening and press in by left and right.(Fig. 8)
Fig. 8
2. Tear the seal with pliers by pulling outward. (Fig. 9)
Fig. 9
3. Keep the hinge down to attach the rectangle damper
4 screws (ST4x6mm)
Fig. 10
4. Use Duct Tape to ensure joint is sealed and air tight.
NOTE: Only punch the vent hole where you want to use. Do
not punch more than 1 vent hole, otherwise, the air power
suction will be reduced.
Hinge

Electrical Connection

Prepare the Wiring Connection
Power cord connection: Use the factory default power cord
(through the hole A) to connect with power supply. (Fig. 11)
Fig. 11

Installation of the Range Hood

1. Put the range hood on a flat surface with the filter facing up.
2. Press the two release tabs on the grease filters to release
Fig. 12
properly. Fix rectangle damper to the rear by 4 screws
(ST4x6mm). (Fig. 10)
NOTE: Damper must be verified that it closes properly.
WARNING
ELECTRICAL SHOCK HAZARD
● Disconnect power before servicing.
● Replace all parts and panels before operating.
● Failure to do so can result in death or electrical shock.
them from the range hood. Remove the grease filters from the
range hood. (Fig. 12)