Troubleshooting - Pentair SUPERFLO Manual De Instalación Y Guía Del Usuario

Bomba de alto rendimiento
Ocultar thumbs Ver también para SUPERFLO:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Problem
Possible Cause
Pump failure.
Pump will not prime - Air leak, too much air.
Pump will not prime - Not enough water.
Pump stainer gasket is clogged.
Pump strainer gasket is defective.
Reduced capacity and/or
Air pockets or leaks in suction line.
head.
Clogged impeller.
Pump strainer clogged.

TROUBLESHOOTING

Corrective Action
Check suction piping and valve glands on any suction
gate valves. Secure lid on pump strainer pot and be
sure lid gasket is in place. Check water level to be
sure skimmer is not drawing air.
Be sure the suction lines, pump, strainer, and pump
volute are full of water. Be sure valve on suction line
is working and open (some systems do not have
valves). Check water level to make sure water is
available through skimmer.
Clean pump strainer pot.
Replace gasket.
Check suction piping and valve glands on any suction
gate valves. Secure lid on pump strainer pot and be
sure lid gasket is in place. Check water level to be
sure skimmer is not drawing air.
Turn off electrical power to the pump.
Disassemble (see page 5, 'Pump Disassembly')
Clean debris from impeller. If debris cannot be
removed, complete the following steps:
1. Remove left hand thread anti-spin bolt and o-ring.
2. Remove, clean, and reinstall impeller.
Reassemble (see page 6, 'Pump Reassembly')
Clean suction trap.
SUPERFLO
High Performance Pump Installation and User's Guide
®
7

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido