Electrical Connection - ELICA Shy Montaje Y Modo De Empleo

Tabla de contenido

Publicidad

Installation
The minimum distance between the supporting surface for the
cooking equipment on the hob and the lowest part of the
range hood must be not less than 45cm from electric cookers
and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
As described in the installation drawings perform 6 holes (8
mm diameter, 40 mm deep), in the positions shown in the
drilling template, to fix the hood support bracket and the
exhaust flue. After installation, check that the hood and
exhaust flue are perfectly aligned.
The range hood is intended to be installed over a hob
having 6 heating elements.

Electrical connection

The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains
cable is correctly assembled.
Warning! If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly qualified
persons in order to avoid hazard.
Mounting
Before beginning installation:
Check that the product purchased is of a suitable size for
the chosen installation area.
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
Operation
First speed (T1)
Press T1 to activate the first speed. When the function is
activated, the LED turns on with a fixed light. Press T1 again
to turn the hood off.
Second speed (T2)
Press T2 to activate the second speed. When the function is
activated, the LED turns on with a fixed light. Press T2 again
to turn the hood off.
Third speed and BOOSTER (T3)
When the hood is off or with the first or second speed active,
the third speed can be activated by pressing the button T3
and the LED will turn on with a fixed light.
If T3 is pressed again, the booster turns on. The booster can
only be activated if the third speed is already active. When the
booster is on, the LED T3 starts to flash. While the booster is
working, it is possible to switch to the first or second speed by
pressing the desired speed button T1 or T2, the booster will
turn off and the selected speed will be activated.
When the booster is on, press T3 again to turn the hood off.
After 5' the booster automatically turns off and the third speed
is automatically activated.
Timer (T4)
The timer can be activated when the first, second or third
speed is active. When the function is activated, both the LED
of the Timer (T4) and that of the previously selected speed
(T1/T2/T3) turn on with a fixed light.
The duration of the timer depends on the selected speed:
First speed T1 = duration 20'
Second speed T2 = duration 15'.
Third speed T3 = duration 10'.
The timer cannot be activated when the booster is active.
When the time expires, the hood turns off. When a speed is
timed, it is possible to switch to other speeds by pressing the
desired speed button, this operation will turn the timer off.
When a speed is timed, the timer can be deactivated by
pressing T4, or one of the other two inactive speeds. To turn
the hood off, press the speed again to which the timer had
previously been linked.
Light (T5)
The light can be activated at any time by pressing key T5.
When the function is activated, the LED turns on with a fixed
light.
14

Publicidad

Tabla de contenido
loading

Tabla de contenido