Electrical Connections for Three-Phase AC, continued
Figure 20 – Schematic, Lifts Wired for Three-Phase AC
Note: Ensure lift structure is grounded per electrical code requirements as required by lift
electrical configuration, i.e. lift contains mounted electrical components.
Figure 21 – Hydraulic Connections
Main power
Tank
Filler
Filter and
suction line
24
Southworth Owner's Manual -- LS Series
Connectors near lift table
unit
(external power units only)
Motor
Pump
Down
valve
Hydraulic supply line
Vent/return line
Connectors near main power unit
(external power units only)
Hydraulic
cylinder
(down speed control)
Hydraulic
cylinder
Flow control