06.4 LOWER LIMIT SWITCH BY PRESSURE - UPPER LIMIT SWITCH BY PRESSURE
Connect the power supply
1-
Bring the roll-up shutter in a intermediate position
2-
Move briefly the roll-up shutter downward
3-
Press together UP and DOWN until the motor makes two alternate
4-
movements (circa 5 secondi), then release the buttons
Press and hold DOWN until the motor stops automatically on the
5-
lower limit switch by pressure
Press and hold UP until the motor stops automatically on the upper
6-
limit switch by pressure
(*) until the installation procedure is finished, the movement of the motor is preceded by a small click
NOTE: to optimize the behavior near the upper limit switch, read section 09 "Early stop" and 10 "Close pressure»
07. FINE ADJUSTMENT OF THE UPPER LIMIT SWITCH
NOTE:
The modification of the upper limit switch is not possible if the limit switch has been learned by contact with an obstacle.
WARNING:
During the execution of points 02 to 06 always keep the DOWN button
01. Bring the motor to the upper limit switch (or close to it).
02. Press together UP and DOWN for 1 second, then release UP (keeping pressed DOWN)
03. (Keep pressing DOWN) wait 3 seconds.
04. (Keep pressing DOWN) press briefly and quickly 3 times UP.
05. (Keep pressing DOWN) wait 3 seconds.
06. (Keep pressing DOWN) press the UP button until the motor signals DOWN-UP (about 2 seconds), then release the buttons.
07. Using UP and DOWN buttons, bring the motor into the new upper limit switch (the motor moves in small steps).
08. Press together UP and DOWN until the motor signals DOWN-UP (about 2 seconds), then release the buttons. Upper limit switch modified!!!
08. FINE ADJUSTMENT OF THE LOWER LIMIT SWITCH
NOTE:
The modification of the lower limit switch is not possible if the limit switch has been learned by contact with an obstacle.
WARNING:
During the execution of points 02 to 06 always keep the UP button
01. Bring the motor to the lower limit switch (or close to it).
02. Press together UP and DOWN for 1 second, then release DOWN (keeping pressed UP)
03. (Keep pressing UP) wait 3 seconds.
04. (Keep pressing UP) press briefly and quickly 3 times DOWN.
05. (Keep pressing UP) wait 3 seconds.
06. (Keep pressing UP) press the DOWN button until the motor signals UP-DOWN (about 2 seconds), then release the buttons.
07. Using UP and DOWN buttons, bring the motor into the new lower limit switch (the motor moves in small steps).
08. Press together UP and DOWN until the motor signals UP-DOWN (about 2 seconds), then release the buttons. Lower limit switch modified!!!
*