Inputs - CDVI A22K Manual Del Usuario

Controlador de alta seguridad (2 puertas/4 lectores)
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN

INPUTS

The A22K can monitor the state of up to 6 devices (12 using zone doubling) such as magnetic contacts, motion
detectors, temperature sensors, or other devices. The following are examples of the type of inputs that can be
monitored:
Magnetic Door Contact:
Permits supervision of door "status" (opened, closed, opened too long, forced open). Inputs "Door
Contact 1" and "Door Contact 2" are assigned by default. When a magnetic door contact is installed,
the system can differentiate between a door forced open and an authorized exit.
Request to Exit (REX):
The device used can be a push button, vertical-view motion detector or floor mat sensor. Inputs "REX
1" and "REX 2" are assigned by default for Door 1 and Door 2 REX inputs respectively.
Two Extra Inputs
(4 using zone
doubling)
Remove the jumper
!
before installing
the door contact
See "Recommended Wiring" section for more information on wiring type, size, and maximum length.
High Security Access Control 2-Doors Module
ETHERNET
PORT
+12V DC
RS485
LOCAL
A+
BUS
B-
Input 1
EXTRA
Input 2
INPUTS/
Output 1
OUTPUTS
+12V DC
Output 2
READER DOOR 1
READER DOOR 2
BUZ GRN RED D1
D0 GND 12V
BUZ GRN RED D1
N.C. Door Contact
ETHERNET
LOCAL BUS
24V DC INPUT/
STATUS
BATTERY/
MODULE TYPE
SYSTEM STATUS
INPUT
INPUT
DOOR 1
DOOR 2
D0 GND
12V
C1
GND
REX1
12V
C2
GND
REX2
N.C. REX1
Door 1
Factory Default Input Settings
(same settings for door 2)
A22K
LOCK 1 & 2
JUMPER SETTING
INPUT
POWER
SUPPLY
BATTERY
BACKUP
ENCLOSURE
TAMPER
LOCK
SWITCH
INPUT
DOOR 1
12V
GND
TMP
LK1+ LK1-
C1 NO1 NC1
LK2+ LK2-
N.C.
+12Vdc
Com.
-
+24V DC
-
+12V DC
-
LOCK
DOOR 2
C2 NO2 NC2