Install panel unit
1. Fix panel into the wall (1), fastening it down along the wall tightly (2) . Ensure that panel and fixing bracket is
completely combined.
2. Use a hex wrench to screw clockwise (3) till it is completely fixed. For disassembling the panel, you may operate this
operation counterclockwise.
1
3. Setting
Distance adjustment
Follow below steps to limit detection distance in reduced space enviroment.
>10sec
>10sec
Approach a magnet to IR
window for >10sec
Flushing mode selection
When the interval between two
Water saving mode
Intensive clean
5~10sec
5~10sec
Approach the magnet to the IR sensor (5-10s).
Led will flash one time
3
2
Access to the
DISTANCE
ADJUSTMENT MODE
Note: For auto adjustment, make sure no object is located in the detection range during
setting timing. If you would like to manually adjust the distance please put an object (such
us white paper) in the desired distance during the setting time.
Pre-flush
users is more than 30min
Always
Access to the
FLUSHING
SETTING MODE
Attention:
Protect the product while installing the panel for
preventing to leave scratches on the surface of product.
While using a wrench for fixing, please do not use it
forcibly for preventing to damage the mechanism.
LED will flash for 5 times
and IR will automatically
adjust distance
Main flush
Half volume when the interval
between two users is 5min.
Always
2~3sec
Approach the magnet to
the IR sensor (2-3s) and
remove it.
Led will flash one time.
WATER SAVING MODE
Wait for 10s to finish the setting.
2
Deodorizer function
No
Flush if more than 3 users
during 2 min.
2~3sec
Wait for 4-5s and approach
the magnet to the IR sensor
(2-3s) and remove it.
Led will flash for two times.
INTENSIVE CLEAN MODE