4. Operational working procedure
In case that the induction time is less than 2sec, the product will not be activated. While the induction time is more than
2sec, pre-flush will be implemented. If the detection is longer than 7sec, flush will be activated after leaving sensor
induction range.
detection time
7 sec
Environment protection flushing mode
In case that this product has not been used for a long period of time, full flush will be automatically activated every 24 hours.

5. Maintenance mode

When this device needs to be repaired, it is not necessary to remove the sensor. Just apply a piece of tape on the sensor
window, the flush after use will be stopped, and you can be free to repair it.
Manual flush
1. You may switch to manual flush mode while there is request for cleaning or other purpose.
2. Attach the magnet during 1sec at the top right part of sensor for entering into manual mode. Under manual mode,
sensor will be deactivated for 5 min,after that, it will be performed with 1min flush. ( Apply with magnet during flushing
if you would like to stop flushing and return to automatic sensor mode).
If during manual mode you would like to advance 1 min forced flush, please attach magnet again at top right part of
sensor. Product will be flushed for 1 min and returned to automatic sensor mode.
<1sec
Switch off flush
In case that there is demand for maintenance or cleaning while the flush switching off is required, you may apply with
below solutions:
1. Enter into manual flush mode.
2. Disassemble panel and disconnect the sensor with power.
Low battery indication / battery replacement (
While the sensor indicator
While the indicator
and flushing. It requires user to replace the batteries.
For the instructions of replacing batteries, please refer to chapter battery replacement of manual .
(fixed-time flushing / automatic cleaning)
flickers every 2 seconds which stands for the batteries are going to be run out of use.
is on continuously which means the batteries are already run out, this product is stopped sensing
Sensor light
Flush activated after user is
not occupied within sensitive
range.
<1sec
)
DC type
3
Sensor magnet

Publicidad