Instructions for Use
EN
The system is a two piece collecting device for ostomates
or urostomates with:
• A base plate with a skin protector and soft flange, also
available* with soft convexity.
• Different types of collecting pouches* :
- Closed,
- Drainable with integrated outlet, Roll'Up or with cap,
or Maxi Drainable.
- For urostomy, with a drain tap.
The unique feature of the system is an integrated guiding
system that allows easy positioning of the adhesive pouch
onto the flexible base plate.
1
Before application
Separate the cardboard from the base plate.
If you are using a cut-to-fit pouch, cut the skin protector
so it fits around your stoma, taking good care not to cut
beyond the limit. Leave a 2 to 3 mm gap around your
stoma: it should not be "occluded" by the skin protector (A).
2
Skin preparation
Wash your hands.
Clean the skin around your stoma with tepid water. Ether,
alcohol and other antiseptics may prevent the base plate
from staying in place, and should therefore be avoided
Dab the skin carefully with soft tissues.
Application of the base plate
3
Remove the clear release from the base plate.
Place the base plate over your stoma, slot of the guiding
system toward the bottom.
Make the skin protector adhere correctly by pressing
1
gently onto the skin under the flange, avoiding forming
folds (B).
If you use a belt with the convex base plate, choose two
notches that are diametrically opposed (C, D).
4
Application of the pouch
Separate the pouch walls by crumpling it slightly to
introduce air into it.
Remove the release paper that protects the adhesive
of the pouch (E).
Insert the tab of the pouch into the slot of the base plate
(F) and (G). Avoid placing your fingers on the adhesive.
Adjust and make the pouch adhere onto the base plate
without making folds (H).
Apply the adhesive carefully by exerting a pressure onto
the stuck area (I).
Make sure the pouch is well secured by pulling on it
slightly.
Tips :
Visual control for good positioning of the pouch : The
white tab of the pouch must be seen in the opening of
the base plate (see H).
The rim of the track must remain visible all around the
pouch adhesive.
If it is necessary to give the pouch a different orientation,
stick the pouch onto the base plate with caution, without
using the guiding system.
5
Removal of the pouch
Maintain the base plate by the prehension tab and
unstick the pouch progressively with the other hand by
pulling on the tab of the pouch (J).
For Urostomy pouch*, unstick the pouch either with