Introduction; Inactivity Of The Panel; Installation; Technical Data - DAB E-BOX 2G M Instrucciones Para La Instalación Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 94
Ensure that the panel has not suffered any
damage during transport or storage.
In particular, check that all the internal parts of
the
panel
(components,
completely free from traces of humidity, oxide or
dirt:
if necessary, clean accurately and check the
efficiency of all the components in the panel. If
necessary, replace any parts that are not perfectly
efficient.
It is indispensable to check that all the panel leads
are correctly tightened in the respective clamps.
In the event of a long period of inactivity (or when
any component has been replaced), it is advisable
to perform on the panel all the checks indicated by
standard EN 60730-1.

3. INTRODUCTION

This
documentation
indications for the installation and use of E-Box
electric panels.
The appliances have been designed and made for
the control and protection of Domestic units and of
Filling and Draining units with 1 or 2 pumps.

4. INACTIVITY OF THE PANEL

A long period of inactivity in precarious conditions
may cause damage to our appliances, making them
become dangerous for the personnel in charge of
installation, checking and maintenance. It is good
practice, above all, to install the panel correctly,
taking particular care to comply with the following
indications.
the panel must be kept in a completely dry
place, far from sources of heat;
the electric panel must be perfectly closed and
isolated from the outside environment, so as to
avoid the entry of insects, humidity and dust
which could damage the electrical components,
jeopardising their regular operation.

5. INSTALLATION

Strictly respect the electric supply
values indicated on the electrical
data plate.
Although the panel has a grade of protection
IP55, it is not advisable to use it in an
atmosphere charged with oxidising or corrosive
gases.
If installed outdoors, the panel must be
protected as much as possible against the
direct rays of the sun.
leads,
etc.)
supplies
the
general
ENGLISH
It is necessary to take suitable steps to keep the
temperature inside the panel within the "limits of
environment temperature use" listed below.
are
High temperatures can lead to accelerated ageing
of all the components, resulting in more or less
severe malfunctions.
It is also recommended that the person carrying
out installation should ensure the cable clamps are
watertight.
Accurately tighten the cable clamps where the
power cable enters the panel and those of any
external controls, connected by the installer, so as
to ensure that the cables cannot work loose from
the clamps.

6. TECHNICAL DATA

6.1 Electrical data

- Power supply:
- Frequency:
- Grade of protection:

6.2 Operating conditions

- Number of pumps that can be
connected:
- Max. use rated power:
- Max. use rated current:
- Environment temperature:
- Storage temperature:
- Air relative humidity:
- Max. altitude:
- Panel construction:
- Capacitor:
(only for E-BOX 2D 40µF)

6.3 Management of the pumps (Applications)

The
panel
electropumps against:
overloads
automatic reset,
short circuits with replacement of fuses.
Set up for inversion of the starting order of the two
electropumps at each start or every 24 hours and to
start one of the two in the event of breakdown of the
other.
The panel is able to work also running only one pump
(see DS_A7-8).
38
1 x 230V
3 x 230/400V
50/60 Hz
IP55
2
400V = 5,5kW + 5,5kW
230V = 3kW + 3kW
12A + 12A
-10 ÷ 40°C
-25°C ÷ 55°C
50% at 40°C
90% at 20°C
1000 m (a.s.l.)
EN 60730-1
40µF + 40µF
is
self-protected
and
and
excess
temperature
protects
the
with

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E-box 2g tE-box 2d m/tE-box 2d 40µf

Tabla de contenido