4. Product description

4.1. Indicators and operator controls
SpillGuard® top view
SpillGuard® bottom view
LED
"Red" LED
The "red" LED illuminates during commis-
sioning, operation and when an alarm is
triggered.
18/42
SpillGuard® Quick Guide | 271433 | Rev. 2
push
The push button is used to switch SpillGuard®
on and off and also to turn off the signal when
"Red" LED
an alarm has been triggered.
Push button

4.2. Technical data

Device marking
II 1G Ex ia IIB T4 Ga
Operating tem-perature
range:*
Temperature class
Foot
Explosion protection
Sensor
group
surface
Ignition protection type Intrinsically safe
Equipment category
Dimensions
Weight
Nominal voltage
Duration of use
Liquid level required to
wet the sensor
Push button
0°C bis 40°C
T4 (max. 135°C)
IIB
1G
Ø 110 mm,
Height 40 mm
140 g
3,6 V
max. 5 years
6 mm