and Address fields;
- Gate-info: two alerts are sent to the user: one when the as-
sociated key is pressed and one when it is released. It is typi-
cally used to notify the gate opened/gate closed states: these
alerts are handled by all the internal stations in the system,
by flashing a special Led (if on the device); for the EX362
or EX3262 internal stations, this alert will be displayed only
from the user stated in the subsequent Block and Address
fields).
Enter the menu, use the
tion you want to associate and then press key
will be highlighted in bold text. Continue with the next selection
(until you associate all the required functions) or press key
to exit and move to the next programming.
-Time intervals
(No time slot associated by default.) Inputs PB, P2 and P3 can
be associated with up to 8 time slots in which input enabling
will determine the execution of the actions you set (for exam-
ple, the Trade function for the postman). If no time slot is asso-
ciated, input enabling will always trigger the set actions. In this
programming item, you can only assign time slots to various
inputs. The 8 time slots can only be programmed via Blue-
tooth. For a correct operation of the device with time slots, you
need to install the XE2921 or XE2922 for the system clock.
Enter the menu, use the
slot you want to associate and then press key
will be highlighted in bold text. Continue with the next selection
(until you associate all 8 time slots) or press key
move to the next programming.
Attention: If an input has one or more time intervals as-
sociated, but the device is not synchronised with the system
clock or synchronisation is lost, the actions will no longer be
executed until the next synchronisation.
- Block
(255 by default, not programmed.) System block to send Call
and Ring-me actions (or any Gate-info), from 01 to 99. See
paragraph Entering a numeric value to learn how to enter
addresses. If the video intercom system is not to be used with
block splitting, do not change the default value or enter 0
- Address
(255 by default, not programmed.) System address to send
Call and Ring-me actions (or any Gate-info), from 001 to 200
(addresses 211 to 220 are also allowed and they are for send-
ing an enabling command directly to an actuator. Think about
turning on lights on the staircase. For this service, you must
program the corresponding actuators so that they can be ena-
bled from the external station). See paragraph Entering a nu-
meric value to learn how to enter addresses.
Admin. password
(0039 by default.) It can be changed with a new one, at the
choice of the installer or the system manager. Press key
enter programming. To enter the password (1 to 8 digits) see
section Entering a numeric value.
Attention: Write down and keep the password in a secure
place; you cannot log in and program the device without it.
Miscellaneous
In this menu section, you can program the general functions of
the system, which are:
- Welcome messages
- Date format
- External CAM
-
key to call
-
key for PWD
- LCD contrast
- Reset user memory
- Release
Use the
and
arrows to select the function, use key
confirm your selection. Press key.
and
arrows tto select the func-
. The item
and
arrows to select the time
. The item
to exit and
to return to the previous
menu.
Welcome messages
During normal operation, a message will be displayed on the
keyboard screen, with essential instructions for making a call.
This message can be disabled or alternated with the date/time
display and/or two custom messages of 4 lines and 20 charac-
ters each. Press key
turn to the previous menu. The following items will be displayed:
- Instruction
- Date and time
- Personal messages
Use the
and
and press key
to confirm.
Instruction
(Enabled by default) Press key
following items will be displayed:
- Disable
- Enable
Inside the menu, use the
sired item, then press key
Date and time
(Enabled by default) Press key
following items will be displayed:
- Disable
- Enable
Inside the menu, use the
desired item, then press key
exiit. The XE2921/XE2922 card must be installed to display
the date and time.
Personal messages
(Disabled by default.) Press key
use the
and
2, then press key
displayed:
- Disable
- Enable
- Edit
Inside the menu, use the
desired item, then press key
confirm the edited entry, you can insert or edit the 4 lines of
text for each message. Use the
the line you want, then press key
20 characters (letters, digits and special characters) are avail-
able; see paragraph Entering a text string to learn how to
make text entries. You can edit other lines or press key
to return to the previous menu. At this point, you must select
and confirm the entry for enabling the message you have just
to
entered. Press key
aligned at the centre on each line.
Date format
(YY.MM.DD. by default) If the date display is enabled, you can
use this menu to choose the date format. Press key
this menu. The following options will be displayed:
- YY.MM.DD
- MM.DD.YY
- DD.MM.YY
Use the
and
arrows to select the desired option and press
key
to confirm. Press key
External CAM
(Disabled by default) If you enable this function, the external
station will handle an external video camera that is directly con-
nected to it, in addition to the camera on the device. When a
command to enable the second video camera arrives from the
video intercom, the external station will switch to the auxiliary
to
camera and then, if any in the corresponding address section,
to the cameras connected to the external modulators, and then
to enter this menu. Press key
arrows to select the item you want to modify
to enter programming. The
and
arrows to choose the de-
to confirm. Press key
to enter programming. The
and
arrows to choose the
to confirm. Press key
to enter programming,
arrows to choose Message 1 or Message
to confirm. The following items will be
and
arrows to choose the
to confirm. If you select and
and
to enter or edit the text.
to exit. Characters are automatically
to return to the previous menù.
to re-
to exit.
to
arrows to choose
to enter
Mi 2565