CONNECTING OPTIONS
CONNECTING TO HARD PIPES
Use the 2-piece pipe connector (D) and appropriate pipe seals (B) according to the pipe size being
connected to.
Refer to diagram; unscrew to top section of D and insert pipe seal B with the wider internal diameter
towards the pipe to be sealed.
Refit the top section of D and lightly tighten.
Push the assembly over the pipe to be sealed and tighten top section of D to provide a better seal.
Connect one end of the 6mm plastic hose (E) to (D) (push-fit) and the other to the gauge.
In some cases it will be necessary to seal off an open pipe to prevent excessive coolant loss.
Use an adaptor as above and then seal the adaptor with component C.
CONNECTING TO HOSES
Slide the male hose connector (F in components diagram) into the hose as far as it will go.
Secure with hose clip if required. Connect one end of the 6mm plastic hose (E) to F (push-fit) and the
other to the gauge.
To disconnect the plastic hose from the push-fit connectors, simply push the outer collar of the push-
fit connector inwards and withdraw the plastic hose.