Commissioning
Information on commissioning
Manual and PC-supported program-
ming are available for programming
the DRM 612-... Once one type of
programming has been selected, this
must be maintained and cannot be
subsequently changed.
Programming with PC
• For programming names, the
programming software PRS 602-0
and programming interface
PRI 602-... USB are required. Names
are entered in the display call
module using the PRS 602-0 from
V 1.3.1.
• Other languages are available via
the PRS 602-...
Procedure
Starting the programming mode
This display appears after you have
switched on the voltage at the dis-
play call module.
Entering your PIN
Factory-set PIN "2222"
Change PIN
(This enquiry procedure only takes
place on initial programming.)
Define your new 4-digit PIN and
make a note of it, together with
the location of the DRM 612-...To
confirm, enter the same PIN again
and then hold down the OK button
for 3 seconds.
Language
Other languages are available via
the PRS 602-...
Manual programming
• Programming, which is carried
out manually at the DRM 612-...,
is protected by a PIN and cannot be
manually bypassed.
• If you cannot remember the PIN,
this can only be read out via the
PRS 602-...
• For servicing purposes, you should
note the installation location and PIN
of each individual DRM 612-... in
order to ensure rapid access to the
stored data, for instance when there
is a change of tenant.
Function button(s)
OK (5 s)
OK (3 s)
OK
OK (3 s)
OK
OK
Remarks
During programming, please always
note the bottom line, which contains
different and changing information.
Follow the programming explana-
tions below until you have pro-
grammed the necessary entries in
the DRM 612-...
Requirement:
• The device has been correctly and
professionally installed and con-
nected
• Power is connected
• The address is set (see Fig. 1)
Display indicator
K. Daten vorhanden
Programmierung am
DRM oder über PRS
Vorgehensweise
PIN input
Sign search
Change PIN
Sign search
Acknowledge PIN
4711
Acknowledge OK (3 s)
PROGRAMMING INDEX
Language
Basic state
Scroll with
11