BML SGA-AEZ1-LZZZ-ZU11-S115
Absolute Magnetically Coded Position Measuring System
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The BML magnetic linear encoder is intended for
communication with a machine control (e.g. PLC). It is
intended to be installed into a machine or system and
used in the industrial sector. Flawless function in
accordance with the specifications in the technical data is
ensured only when using original Balluff accessories. Use
of any other components will void the warranty. Non-
approved use is not permitted and will result in the loss of
warranty and liability claims against the manufacturer.

Downloading further instructions

A complete user's guide and the magnetic tape user's guide
can be downloaded from the Internet at www.balluff.com
or requested via e-mail from service@balluff.de.
Installation and connection
BML SGA-...-S115
LED
Active measuring surface
Ballu JJWW .xxDE Abs Code L
4
Interference in function
Improper assembly of the magnetic tape and sensor head may impair function of the position measuring system and lead to
increased wear or damage to the system.
► All permissible distance and angle tolerances must be strictly complied with.
► The sensor head may not come into contact with the magnetic tape over the entire measuring range. Contact must
also be avoided if the magnetic tape is covered by a cover strip (optional).
► The position measuring system must be installed in accordance with the indicated degree of protection.
► Strong magnetic fields ≥1 mT, in particular magnetic clamps, must not affect the system.
1
english
12.3
54.6
(2x) Ø 4.3
Sensor head
Left
Right
19
NOTICE
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the linear encoder will
not result in hazards to persons or equipment.
If defects and unresolvable faults occur in the linear
encoder, take it out of service and secure against
unauthorized use.
25
10.6
Active measuring surface
Sensor head
Ballu JJWW ._ _DE Abs Code E
Magnetic tape
File no.
E227256
16 +0.2