Descargar Imprimir esta página

Balluff BML SGA-AEZ1-LZZZ-ZU11-S115 Instrucciones Breves página 8

Ocultar thumbs Ver también para BML SGA-AEZ1-LZZZ-ZU11-S115:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
BML SGA-AEZ1-LZZZ-ZU11-S115
Absolute Magnetically Coded Position Measuring System
Construction and function (continued)
Connectors S115
The electrical connection is made using a connector.
If the sensor is powered by a source separate
from the processing electronics, the grounds of
the sensor and processing electronics must be
connected.
Pin assignment of S115 plug (M12, 8-pin), view from
above on sensor head)
Pin
1
2
3
4
5
6
7
8
Shield
1) Unassigned leads must not be connected.
2) If not used, then connect to GND (recommended) or leave unconnected.
3
english
Signal
VDD
Not used
1)
+Rx
–RX
GND
–TX
+Tx
Preset
Shield
Description
Supply voltage 10...30 V DC
Receive DRIVE-CLiQ signals
Receive DRIVE-CLiQ signals
Sensor ground (0 V)
Send DRIVE-CLiQ signals
Send DRIVE-CLiQ signals
Digital input
2)
, sets the current position to approx. 10 mm
(Connector housing to) shield

Publicidad

loading