7. Pull the motor cable through the rear cover over the
terminals and fasten it to the power terminals U/T1,
V/T2, W/T3 and PE on the frequency inverter.
— Connect wire 1 to power terminal U/T1.
— Connect wire 2 to power terminal V/T2.
— Connect wire 3 to power terminal W/T3.
— Connect wire GN/YE to power terminal PE.
13:
Motor cable connection
8. Pull the connection cables of line choke L1
and
(2)
and the cable with the suppression
capacitor
14 (3)
through the rear cover over the
terminals and connect it to the terminals P0 and
PA/+ on the frequency inverter.
— Connect wire 1 to power terminal P0.
— Connect wire 2 together with the cable with the
suppression capacitor to power terminal PA/+.
14:
Connecting cables
Robert Bosch GmbH
15:
Line choke L1 connection
9. Connect the voltage supply (3 cables with
suppression capacitors) to power terminals R/L1,
S/L2, T/L3 and PE on the frequency inverter as
follows:
From device / terminal
K1 / 1(L1)
K1 / 3(L2)
14 (1)
K1 / 5(L3)
X1 / PE
16:
Power supply connection
10. Remove jumper JP1
11. Secure jumper JP1
(1)
. To secure, use the lower slot on the actuator.
1 687 011 538 | 15 | en
To device / terminal
A11 / R/L1
A11 / S/L2
A11 / T/L3
A11 / PE
17
(2).
17 (2)
with a cable tie
17